Response Stage: Trillium-240 Generation 2 PZ
Name: | Trillium-240 Generation 2 PZ | Correction: | |
---|
Stage Index: | 1 | Sample Offset: | 0.0 |
---|
Stage Type: | Poles & Zeros | Decimation: | 1.0 |
---|
Input Units: | M/S | Input Sample Rate: | |
---|
Output Units: | V | Gain: | 1189.0000000 |
---|
Transfer Function Type: | Continuous | Gain Frequency: | 1.0 |
---|
Delay: | 0 s | Symmetry: | None |
---|
Poles & Zeros
There areShowing 1 of 17 poles & zeros.
Type |
Index |
Value |
Action |
Pole |
1 |
-0.01770+0.01760i |
|
Pole |
2 |
-0.01770-0.01760i |
|
Pole |
3 |
-85.30000+0.00000i |
|
Pole |
4 |
-155.40000+210.80000i |
|
Pole |
5 |
-155.40000-210.80000i |
|
Pole |
6 |
-713.00000+0.00000i |
|
Pole |
7 |
-1140.00000+0.00000i |
|
Pole |
8 |
-4300.00000+0.00000i |
|
Pole |
9 |
-5800.00000+0.00000i |
|
Pole |
10 |
-4300.00000+4400.00000i |
|
Pole |
11 |
-4300.00000-4400.00000i |
|
Zero |
1 |
0.00000+0.00000i |
|
Zero |
2 |
0.00000+0.00000i |
|
Zero |
3 |
-72.50000+0.00000i |
|
Zero |
4 |
-159.30000+0.00000i |
|
Zero |
5 |
-251.00000+0.00000i |
|
Zero |
6 |
-3270.00000+0.00000i |
|