Response Stage: Trillium-40 PZ
Name: | Trillium-40 PZ | Correction: | |
---|
Stage Index: | 1 | Sample Offset: | 0.0 |
---|
Stage Type: | Poles & Zeros | Decimation: | 1.0 |
---|
Input Units: | M/S | Input Sample Rate: | |
---|
Output Units: | V | Gain: | 1553.0000000 |
---|
Transfer Function Type: | Continuous | Gain Frequency: | 1.0 |
---|
Delay: | 0 s | Symmetry: | None |
---|
Poles & Zeros
There areShowing 1 of 12 poles & zeros.
Type |
Index |
Value |
Action |
Pole |
1 |
-0.11030+0.11100i |
|
Pole |
2 |
-0.11030-0.11100i |
|
Pole |
3 |
-86.30000+0.00000i |
|
Pole |
4 |
-241.00000+178.00000i |
|
Pole |
5 |
-241.00000-178.00000i |
|
Pole |
6 |
-535.00000+719.00000i |
|
Pole |
7 |
-535.00000-719.00000i |
|
Zero |
1 |
0.00000+0.00000i |
|
Zero |
2 |
0.00000+0.00000i |
|
Zero |
3 |
-68.80000+0.00000i |
|
Zero |
4 |
-323.00000+0.00000i |
|
Zero |
5 |
-2530.00000+0.00000i |
|